Revision as of 04:02, 6 September 2024 by Wodie (talk | contribs) (Created page with " = Connectors = * Mains AC Input: 3 Phase + Neutral 220 V 60 Hz. * 01 EtherCon EtherCat Input. * 01 EtherCon EtherCat Output. * 01 L21-30 Motor AC Ouput. * 01 DB9 Encoder Input. * 01 XLR3F Home Switch Input. = Main AC = {| class="wikitable" style="text-align: center; width: 30% !colspan= "3"| Main AC |- ! style="width: 30%"; style="color:black; background-color:green;" | G ! style="width: 30%"; style="color:black; background-color:yellow;" | | Gnd |- ! style="color:bl...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Connectors

  • Mains AC Input: 3 Phase + Neutral 220 V 60 Hz.
  • 01 EtherCon EtherCat Input.
  • 01 EtherCon EtherCat Output.
  • 01 L21-30 Motor AC Ouput.
  • 01 DB9 Encoder Input.
  • 01 XLR3F Home Switch Input.

Main AC

Main AC
G Gnd
W Neutral
X Line 1 (127 V)
Y Line 2 (127 V)
Z Line 3 (127 V)

Inductive Home Sensor XLR3

Home Sensor XLR3
1 0 V
2 Sense
3 24 V


Motor Output L21-30

Motor Output L21-30
G Gnd
W Not Connected
X Line 1 (127 V)
Y Line 2 (127 V)
Z Line 3 (127 V)

Incremental Encoder DB-9

Encoder
1 A+
2 A-
3 B+
4 B-
5 Shield
6 Z+
7 Z-
8 +5 V
9 0 V / Gnd

Pendant

Pendant
1 E-Stop 1A
2 E-Stop 1B
3 0 V
4 24 V
5 Fwd
6 Rev
7 0 V (Analog)
8 10 V (Analog)
9 Speed (Analog)
10 Gnd

Limit Switches

Stromag 51-29-BMOZ-499 recomended.

Limit Switches
1 Up Limit A
2 Down Limit A
3 Up Limit B
4 Down Limit B
5 Slow Up Limit
6 Slow Down Limit
7 Slow