Lift-Drive: Difference between revisions

From WLPS Wiki
Jump to navigation Jump to search
Line 155: Line 155:
| Rev
| Rev
|-
|-
! style="color:black; background-color:orange;" | 7
! style="color:black; background-color:yellow;" | 7
! style="color:black; background-color:orange;" |
| 0 V (Analog)
|-
! style="color:black; background-color:yellow;" | 8
! style="color:black; background-color:yellow;" |
! style="color:black; background-color:yellow;" |
| 10 V (Analog)
| 10 V (Analog)
|-
|-
! style="color:lightgray; background-color:brown;" | 9
! style="color:lightgray; background-color:brown;" | 8
! style="color:lightgray; background-color:brown;" |
! style="color:lightgray; background-color:brown;" |
| Speed (Analog)
| Speed (Analog)
|-
|-
! style="color:lightgray; background-color:blue;" | 10
! style="color:lightgray; background-color:blue;" | S
! style="color:lightgray; background-color:blue;" |
! style="color:lightgray; background-color:blue;" |
| Gnd
| Shield
|-
|-
|}
|}

Revision as of 18:52, 6 September 2024

Connectors

  • Mains AC Input: 3 Phase + Neutral 220 V 60 Hz.
  • 01 EtherCon EtherCat Input.
  • 01 EtherCon EtherCat Output.
  • 01 L21-30 Motor AC Ouput.
  • 01 DB9 Encoder Input.
  • 01 XLR3F Home Switch Input.

Main AC

Main AC
G Gnd
W Neutral
X Line 1 (127 V)
Y Line 2 (127 V)
Z Line 3 (127 V)

Inductive Home Sensor XLR3

Home Sensor XLR3
1 0 V
2 Sense
3 24 V


Motor Output L21-30

Motor Output L21-30
G Gnd
W Not Connected
X Line 1 (127 V)
Y Line 2 (127 V)
Z Line 3 (127 V)

Incremental Encoder DB-9

Encoder
1 A+
2 A-
3 B+
4 B-
5 Shield
6 Z+
7 Z-
8 +5 V
9 0 V / Gnd

Pendant

Pendant
1 E-Stop 1A
2 E-Stop 1B
3 0 V
4 24 V
5 Fwd
6 Rev
7 10 V (Analog)
8 Speed (Analog)
S Shield

Limit Switches

Stromag 51-29-BMOZ-499 recomended.

Limit Switches
1 Up Limit A
2 Down Limit A
3 Up Limit B
4 Down Limit B
5 E-Stop Up Limit A
6 E-Stop Up Limit B
7 E-Stop Down Limit A
8 E-Stop Down Limit B